11/15 EINS 517216
AGA CITY24
(Gas Top Burners)
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
. Do not try to light any appliance.
. Do not touch any electrical switch
. Do not use any phone in your building.
. Immediately call your gas supplier from a neighbors phone.
Follow the gas suppliers instructions
. If you cannot reach your gas supplier call the fire department.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
Installation
Guide
IMPORTANT : SAVE INSTRUCTIONS FOR FUTURE REFERENCE
IMPORTANT : CONSERVER CES INSTRUCTIONS POUR REFERENCE FUTURE
For use in USA/Canada
REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured
conform to the safety and performance specification that we require. Do not use reconditioned or copy
parts that have not been clearly authorised by AGA.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Installation

11/15 EINS 517216AGA CITY24 (Gas Top Burners) Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other

Strany 2 - CONTENTS

CLEARANCESSide ClearancesIf you are installing a AGA City24 in a new kitchen or have the opportunity to set the width between kitchen or units, it isa

Strany 3 - PRODUCT SAFETY

Combustible Rear WallsSince this range can be used continuously, please take note of the IMPORTANT INSTRUCTIONS.Where the rear wall is constructed of

Strany 4 - GENERAL NOTES

LOCATIONCombustible side wall clearance above the gas top plate shall be greater than 3” (76mm).Surfaces over the top of the range must not be closer

Strany 5 - INSTALLATION

13CONNECTION TO THE POWER SUPPLY Electric Shock HazardRating Plate is located behind removable plinth, see Fig. 11.Electrical Grounding is required o

Strany 6 - TECHNICAL DATA

MAINS CABLE ROUTINGFig. 11 DESN 517233THE MAINS SUPPLY MUST BE WITHIN THE ZONES SHOWNIF A RECESSED RANGE CONNECTION IS TO BE USED BEHIND THE RANGE WIT

Strany 7

15CONNECTING TO GASCAUTION: ENSURE THAT THE RANGE IS ISOLATED FROM ELECTRIC SUPPLY.The range can be installed with an approved flexible connection. Su

Strany 8 - 2” (13mm) socket to

COOKER STABILITY A safety chain must be anchored firmly to the wall and cooker to prevent the flexible hose from straining, when the cooker is withdra

Strany 9 - Fig. 8 DESN 517229

PRESSURE TESTINGThe pressure test point is situated just below hotplate level on the rear right hand side of the range. (See Fig. 12).The maximum gas

Strany 10 - CLEARANCES

18Fig. 15AFig. 15CDESN 511617Fig. 15B DESN 513513DESN 513898BURNER CAPRETAINING LUGSASSEMBLY OF BURNERSPLACE BURNER CAP OVER RETAINING LUGS, THEN TURN

Strany 11

TO ADJUST PAN SUPPORT LEVELDESN 517187Fig. 161. Loosen retaining nut using 1/4” (8mm) spanner (See Fig. 16).2. To prevent rocking adjust the pan sup

Strany 12 - LOCATION

SECTION PAGEProduct Safety 3General Notes 4Health and Safety 4General Installation Requirements 4Installation 5Technic

Strany 13

Control Knob and Bezel LocationEnsure control knobs and bezels are located onto spindles correctly, as shown in Fig 17.Handrail Location Locate handra

Strany 15 - CONNECTING TO GAS

Tick Box lCheck pan supports and gas hotplate burners are correctly fitted. lCheck gas pressure is correct.l Check

Strany 17 - PRESSURE TESTING

24www.agamarvel.comSupplied byAGA Marvel1260 E. Van Deinse St.Greenville, MI 48838Business (616) 754-5601Fax (616) 754-9690Toll Free Telephone

Strany 18 - ASSEMBLY OF BURNERS

3PRODUCT SAFETYMEANING/DESCRIPTION SIGNIFICATION/DESCRIPTIONSYMBOLWARNING/CAUTIONAn appropriate safety instruction should be followed or caution to a

Strany 19 - 8” (2.5mm) allen key

HEALTH AND SAFETYConsumer ProtectionAs responsible manufacturers we take care to make sure that our products are designed and constructed to meet the

Strany 20

CAUTION: THIS INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE; ANSI Z223.1 / NFPA 54 OR,

Strany 21 - WIRING DIAGRAM

6GAS TOP BURNERSThis appliance is supplied set for Natural Gas (NG) at a pressure of 4” WC. It must be converted to run on LP Gas (Propane)at a pressu

Strany 22

REMOVAL FROM PALLET AND COOKER INSTALLATIONFig. 1 DESN 517176Removing of transit brackets - Unscrew 4 screws and remove brackets, from front and two s

Strany 23

REMOVAL FROM PALLET AND COOKER INSTALLATIONFig. 5 DESN 517179Appliance can now be pushed back on its wheels into desired position.NOTE: Care must be t

Strany 24

RANGE DIMENSIONS - AGA CITY24 (GAS TOP BURNERS)Fig. 8 DESN 517229APPLIANCE WEIGHT (Excludes Packaging)Model: AGA CITY24 (Gas Top Burners) - 474 lbs (2